Choose suitable types based on your budget, conductive needs and construction surroundings.
XLPE cables carry bigger current with the same wire size. They fit circuits that demand high transmission capacity.
Follow fixed standards for bending radius. Keep radius 4 times cable OD if OD is below 25mm. Use 6 times OD for cables over 25mm thick.
Proper bending size lets workers lay cables smoothly on poles, crossarms and building fixtures.
Aluminum alloy core types cut cable weight without losing good conductivity. They simplify installation and later maintenance work.
Product Advantages
- Outer insulation prevents frequent short-circuit accidents outdoors, raising power operation safety.
- Anti-corrosion insulation slows metal rust in humid, salty and polluted environments.
- Light alloy core versions ease manual transport and cable erection on utility poles.
- Multiple insulation and core options fit different budget and project standards.
- Low-temperature resistance allows construction in cold winter regions without cable damage.
Application Scenarios
Quality & Service Support
We are direct cable manufacturer with affordable wholesale prices for global power contractors and grid suppliers.
Visit our official website: https://yidongjiaolian.com to check full product data and submit your inquiry.
| Model | JKV-0.6/1 (copper core PVC), JKLV-0.6/1 (aluminum core PVC), JKLVH-0.6/1 (aluminum alloy core PVC), JKY-0.6/1 (copper core PE), JKLY-0.6/1 (aluminum core PE), JKYJ-0.6/1 (copper core XLPE), JKLHYJ-0.6/1 (aluminum alloy core XLPE) |
|---|---|
| Rated voltage | 0.6/1kV |
| conductor material | copper, aluminum, aluminum alloy |
| Insulation materials | PVC, PE, XLPE |
| Conductor operating temperature | PVC/PE ≤ 70 ℃, XLPE ≤ 90 ℃ |
| Laying temperature | not lower than -20 ℃ |
| Minimum bending radius | ≥ 4D for outer diameter<25mm, ≥ 6D for outer diameter ≥ 25mm |
| nominal cross-sectional area of conductor | 10, 16, 25, 35, 50, 70, 95, 120, 150, 185, 240, 300 mm ², etc |
| Execution standard | GB/T 12527-2008; Applicable scenarios: 1kV and below overhead distribution lines, rural power grids, and urban low-voltage overhead lines |
| Core x Section (mm²) | Insulation Thickness(mm) | Outer Dia. (approx.mm) | Current Rating in Air(A) | Max.Conductor Temp. (℃) |
| 2×16 | 1.2 | 16.5 | 75 | 90(XLPE) |
| 4×25 | 1.5 | 24.0 | 110 | 90(XLPE) |
| 4×50 | 1.5 | 30.5 | 165 | 90(XLPE) |
| 3×95+1×70 | 1.7 | 42.5 | 255 | 90(XLPE) |
Core×Section(mm²) Insulation Thickness(mm)
| 2×16 | 1.2 |
| 4×25 | 1.5 |
| 4×50 | 1.5 |
3×95+1×70
1.7
Outer Dia. (approx.mm) Current Rating in Air(A)
16.5 75
24.0 110
30.5 165 42.5 255
| Max.Conductor Temp.(C) |
| 90(XLPE) |
| 90(XLPE) |
| 90(XLPE) |